LYGUOHAN / Railway OCS Equipment
AC 25kV · 50Hz National High-Tech Enterprise
Luoyang Guohan Railway Equipment Co., Ltd. Luoyang Guohan Railway Equipment Co., Ltd.

Section Insulator for Electrified Railway OCS (FYFH-2.0AT)

Model FYFH-2.0AT Standard TB/T 3036-2016 Category Section Insulator
FYFH-2.0AT Section Insulator for Electrified Railway OCS (FYFH-2.0AT)
Model
FYFH-2.0AT
Standard
TB/T 3036-2016
Documents & pricing
Type test reports, factory inspection records and quotations are available on request; tender documents are archived by project.
Product DetailsProduct DetailsFYFH-2.0AT

Product Overview

This product is used for electrical sectioning of the overhead contact system (OCS) of electrified railways. Installed between the contact wire and the messenger wire, it achieves electrical isolation between two power supply sections by means of an insulated runner, while allowing the pantograph to pass smoothly.

CRCC Certification Information

ItemContent
Certified unitSection insulator
Certification standardTB/T 3036-2016 "Section Insulators for Overhead Contact System of Electrified Railway"
Certificate No.CRCC10222P12329R1S-002
Certificate validity2026-06-30 to 2027-11-22
Certification bodyChina Railway Test & Certification Center (CRCC)

Technical Parameters

ParameterTechnical Requirement (TB/T 3036-2016)
Product modelFYFH-2.0AT
Model typeType A (maximum working load 16.5kN)
Creepage distance2.0m (standard requirement ≥1600mm)
Air insulation clearance≥430mm
Product drawing No.GHS-FYFH-2.0BT-0
Nominal voltageAC 25 kV
Maximum working load16.5kN
Tensile breaking load≥49.5kN
Routine tensile test load≥24.8kN
Lightning impulse withstand voltage (1.2/50μs)≥160 kV
Power-frequency wet flashover voltage≥87 kV
Artificial pollution withstand voltage (salt deposit density 0.4mg/cm², nonsoluble deposit density 2.0mg/cm²)≥37 kV
Creepage distance≥1600 mm
Initial sliding force≥95% of the comprehensive tensile breaking force of the connected contact wire
Vibration test2×10⁶ cycles at maximum working load, amplitude 35mm, frequency 1Hz~3Hz
Axial fatigue testReduction of tensile breaking load ≤5% after 5×10⁵ cycles
Applicable operating speed≤120 km/h
Ambient temperature-40℃ ~ +40℃
Altitude≤1400m (at higher altitudes the test voltage shall be corrected by the Ka factor)

Model Designation

In accordance with Clause 4.2 of TB/T 3036-2016, the model designation FYFH-2.0AT indicates: a creepage distance of 2.0m, Type A construction, suitable for copper or copper alloy contact wires.

Structural Features

  • Type A construction with a maximum working load of 16.5kN
  • Combination of an insulated runner and a conductive runner, providing both insulation and conductivity
  • The arc horn gap can divert or extinguish by itself the arc generated when the pantograph passes
  • Capable of withstanding repeated continuous passages of the pantograph

Scope of Application

Suitable for same-phase electrical sectioning points of 25kV single-phase AC electrified railway overhead contact systems, at stations and in inter-station sections.

Note: The values in the table are the minimum technical requirements specified by TB/T 3036-2016. The measured values of actual products are subject to the factory test report, which is available on request.