LYGUOHAN / Railway OCS Equipment
AC 25kV · 50Hz National High-Tech Enterprise
Luoyang Guohan Railway Equipment Co., Ltd. Luoyang Guohan Railway Equipment Co., Ltd.

Rigid Section Insulator for Urban Rail Transit (GHT-FYFH-2.0TG-0)

Model GHT-FYFH-2.0TG-0M Standard TB/T 3252-2022 Category Section Insulator
GHT-FYFH-2.0TG-0M Rigid Section Insulator for Urban Rail Transit (GHT-FYFH-2.0TG-0)
Model
GHT-FYFH-2.0TG-0M
Standard
TB/T 3252-2022
Documents & pricing
Type test reports, factory inspection records and quotations are available on request; tender documents are archived by project.
Product DetailsProduct DetailsGHT-FYFH-2.0TG-0M

Product Overview

The rigid section insulator for urban rail transit is used at electrical sectioning points of the rigidly suspended overhead contact system (busbar) of metro, light rail and other urban rail systems, providing isolation between power supply sections.

CRCC Certification Information

ItemContent
Certified unitRigid section insulator for urban rail transit
Certification ruleUrban rail transit busbars and accessories
Certification standardTB/T 3252-2022 "Busbar for Overhead Contact System of Electrified Railway"
Certificate No.CRCC10225P22329R1S-001
Certificate validity2026-04-16 to 2027-11-22
Certification bodyChina Railway Test & Certification Center (CRCC)

Technical Parameters

ParameterTechnical Requirement
Product modelGHT-FYFH-2.0TG-0
Product typeType A
Product drawing No.GHT-FYFH-2.0TG-0
ConstructionRigid suspension (busbar)
Assembled tensile load≥10 kN (Table 7 of TB/T 3252-2022)
Tensile breaking load≥30 kN (Table 7 of TB/T 3252-2022)
Creepage distance≥1600 mm (per TB/T 3036-2016)
Air insulation clearance≥300 mm (per TB/T 3036-2016)
Lightning impulse withstand voltage≥160 kV (per TB/T 3036-2016)
Power-frequency wet flashover voltage≥87 kV (per TB/T 3036-2016)
Artificial pollution withstand voltage≥37 kV (per TB/T 3036-2016)
Applicable systemRigidly suspended overhead contact system of urban rail transit (DC traction)

Note: Clause 5.3.8 of TB/T 3252-2022 stipulates that the technical parameters of the individual insulating components of a rigid section insulator shall comply with TB/T 3036-2016, the assembled tensile load shall comply with Table 7, and all other electrical performance parameters shall comply with TB/T 3036-2016.

Differences from the Railway Rigid Section Insulator

ItemThis Product (Urban Rail)Railway Rigid Section Insulator
Product category52 Urban rail transit traction power supply products15 Railway traction power supply equipment and components
Certified unitRigid section insulator for urban rail transitRigid section insulator
Certificate No.CRCC10225P22329R1S-001CRCC10225P12329R1SSYZ-001
Certification standardTB/T 3252-2022—
Application scenarioMetro, light railElectrified railway

The certificates of the two certification units are independent of each other and cannot substitute for one another.

Structural Features

  • Suitable for rigidly suspended (busbar) overhead contact systems
  • Compact structure, suitable for installation inside tunnels
  • Smooth pantograph transition

Scope of Application

Suitable for electrical sectioning points of the rigidly suspended overhead contact system of urban rail transit systems such as metro and light rail.